Kromschroder
Есть вопросы? Напишите нам.
Каталог товаров
Артикул
Описание
Артикул:BCU 465-3/1LW8GBPS2AE1
Артикул:BCU 465-3/1LW8GBS2A
Артикул:BCU 465-3/1LW8GBS2AE1
Артикул:BCU 465-3/1LWGBA
Артикул:BCU 465-3/1LWGBD2AE1
Артикул:BCU 465-3/1LWGBPACE1
Артикул:BCU 465-3/2LR8GBPAE1
Артикул:BCU 480-10/3/1LR3GB
Артикул:BCU 480-10/3/1LR3GBS3/1U
Артикул:BCU 480-10/3/1LR8GBPD3S3/3
Артикул:BCU 480-10/3/1LRGBS2/1
Артикул:BCU 480-10/3/1LW1GB
Артикул:BCU 480-10/3/1LW1GBD2
Артикул:BCU 480-10/3/1LW1GBE1
Артикул:BCU 480-10/3/1LW1GBPE1
Артикул:BCU 480-10/3/1LW1GBS2/1
Артикул:BCU 480-10/3/1LW1GBS2/1E1
Артикул:BCU 480-10/3/1LW1GBS2/2
Артикул:BCU 480-10/3/1LW1GBS3/1E1
Артикул:BCU 480-10/3/1LW1GBU
Артикул:BCU 480-10/3/1LW3GB
Артикул:BCU 480-10/3/1LW3GBD2
Артикул:BCU 480-10/3/1LW3GBD2E1
Артикул:BCU 480-10/3/1LW3GBD2S3/3
Артикул:BCU 480-10/3/1LW3GBD2UE1
Артикул:BCU 480-10/3/1LW3GBD3S3/1
Артикул:BCU 480-10/3/1LW3GBD3UE1
Артикул:BCU 480-10/3/1LW3GBE1
Артикул:BCU 480-10/3/1LW3GBP
Артикул:BCU 480-10/3/1LW3GBPD2
Артикул:BCU 480-10/3/1LW3GBPD3
Артикул:BCU 480-10/3/1LW3GBS2/1
Артикул:BCU 480-10/3/1LW3GBS2/1U
Артикул:BCU 480-10/3/1LW3GBS2/2U
Артикул:BCU 480-10/3/1LW3GBS4/1
Артикул:BCU 480-10/3/1LW3GBS4/1U
Kromschroder , c 3745 по 3780,заказные номера BCU 465-3/1LW8GBPS2AE1 ... BCU 480-10/3/1LW3GBS4/1U,
классификация Burner control unit, series 400 Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · 2 start-up attempts · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 20 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 4 s · 21 Minimum burner pause time tBP: 8 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для single-electrode operation · Minimum time between two start-ups: 10 s Контроллер Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 4 start-up attempts, pilot burner · 1 start-up attempt, main burner · Configured and prepared для UVD 1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Restart in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер
классификация Burner control unit, series 400 Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · 2 start-up attempts · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 20 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 4 s · 21 Minimum burner pause time tBP: 8 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для single-electrode operation · Minimum time between two start-ups: 10 s Контроллер Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 4 start-up attempts, pilot burner · 1 start-up attempt, main burner · Configured and prepared для UVD 1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Restart in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер