BCU 480-10/3/1LW3GBD2S3/3 Kromschroder

Артикул
BCU 480-10/3/1LW3GBD2S3/3
Дополнительный Артикул
BCU4801031LW3GBD2S33
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during intermittent operation with UVS · 3 start-up attempts, pilot burner · 3 start-up attempts, main burner · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Цена
170 071 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: TAH-R 400 , BASIC, NEW GENERATION, POS.1
Бренд: Kromschroder
Описание: Контроллер
Подробнее
Артикул: BCU 460W3P2C0D0000K1E1-/LM400WF0O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: M32 · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: none · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 2 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 0 s · Burner application: two-stage burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Safety time during operation: 1 s · Minimum burner on time tB: 3 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): Off · Fieldbus communication: no address check · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: BIC 65HD-200/235-(98)F
Бренд: Kromschroder
Описание: · Burner size 65 · Hot air/high furnace temperature · для town gas · Length of steel tube as of furnace flange: 200 mm · Distance from furnace flange to front edge of burner head: 235 mm · Burner head identifier 98 · Construction stage F Контроллер
Подробнее
Артикул: BCU 560WC1F0U0D1K2-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: BCU 580WC1F1U0D1K2-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during continuous operation with ionization/UVD · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 20 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: BCU 480-10/3/1LW3GBD2
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during intermittent operation with UVS · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер