г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

Kromschroder

Есть вопросы? Напишите нам.

Артикул
Описание
5726Артикул:BCU 560WC0F0U0D1K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: multi-flame control (MFC) start-up conditions · 73 Function of terminal 68: multi-flame control (MFC) operating conditions · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5728Артикул:BCU 560WC0F0U0D1K2-E
5729Артикул:BCU 560QC0F1U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5730Артикул:BCU 560QC0F1U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5731Артикул:BCU 560QC0F1U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 06 High temperature operation: during continuous operation with ionization/UVD · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: two-stage burner/pilot burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5732Артикул:BCU 560QC0F1U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: AND gating with emergency stop (terminal 46) · 72 Function of terminal 67: AND gating with emergency stop (terminal 46) · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5734Артикул:BCU 560WC0F1U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: two-stage burner/pilot burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5735Артикул:BCU 560WC0F1U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5736Артикул:BCU 560WC0F1U0D1K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 06 High temperature operation: during continuous operation with ionization/UVD · 07 Burner/pilot burner start-up attempts: 2 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5737Артикул:BCU 560WC0F1U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5738Артикул:BCU 560WC0F1U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5739Артикул:BCU 560QC0F3U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5740Артикул:BCU 560QC0F3U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 8 s · 62 Minimum pause time tBP: 4 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5741Артикул:BCU 560WC0F3U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s Контроллер
5743Артикул:BCU 560WC0F3U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 71 Function of terminal 66: LDS ignition position check · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5744Артикул:BCU 560WC0F3U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5745Артикул:BCU 560WC0F3U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5746Артикул:BCU 560QC1F0U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 51 Valve proving system: permanent tightness test via proof of closure function (POC) · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode unlimited · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5747Артикул:BCU 560QC1F0U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5748Артикул:BCU 560WC1F0U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode unlimited · 77 User-defined password · 78 Burner application: two-stage burner/pilot burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5749Артикул:BCU 560WC1F0U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · 04 Flame control: UVD · 07 Burner/pilot burner start-up attempts: 3 · 09 Restart: no · Safety time during operation: 1 s · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V3 · 56 Measurement time Vp: 3 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 70 Function of terminal 65: AND gating with emergency stop (terminal 46) · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s Контроллер
5750Артикул:BCU 560WC1F0U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V3 · 56 Measurement time Vp: 100 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5751Артикул:BCU 560WC1F0U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5752Артикул:BCU 560QC1F1U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 51 Valve proving system: permanent tightness test via proof of closure function (POC) · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 10 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5753Артикул:BCU 560QC1F1U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 40 Capacity control with IC 20 · 42 Running time: 30 s · 48 Air actuator can be activated externally · 49 Air actuator can be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: permanent tightness test via proof of closure function (POC) · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 72 Function of terminal 67: multi-flame control (MFC) start-up conditions · 73 Function of terminal 68: multi-flame control (MFC) operating conditions · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 10 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5754Артикул:BCU 560QC1F1U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · 04 Flame control: UVD · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 60 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: no address check Контроллер
5755Артикул:BCU 560QC1F1U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5756Артикул:BCU 560WC1F1U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: on; для approaching the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator can be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 72 Function of terminal 67: AND gating with emergency stop (terminal 46) · 73 Function of terminal 68: AND gating with emergency stop (terminal 46) · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5757Артикул:BCU 560WC1F1U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: UVS · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator closed in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 13 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with Low signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s Контроллер
5758Артикул:BCU 560WC1F1U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 30 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5759Артикул:BCU 560WC1F1U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 06 High temperature operation: during intermittent operation with UVS · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test after shut-down · 52 Relief valve (VPS): V3 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
5760Артикул:BCU 560WC1F1U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: Tightness test beдляe start-up and after shut-down · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Kromschroder , c 5725 по 5760,заказные номера BCU 560WC0F0U0D0K2-E ... BCU 560WC1F1U0D1K2-E,
классификация Burner control unit Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · No capacity control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s Контроллер Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: Tightness test beдляe start-up and after shut-down · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер

Не нашли то, что искали?

Оставьте своё имя и номер телефона, и наш менеджер свяжется с вами в течение 15 минут