TJ 0300-A1AHATND2E8XSB0 Kromschroder

Артикул
TJ 0300-A1AHATND2E8XSB0
Дополнительный Артикул
TJ0300A1AHATND2E8XSB0
Бренд
Kromschroder
Описание
Model: 0300 - 3 000 000 Btu/h (879 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 1 - Furnace Less Than 1750 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: H - High Velocity Outlet · CombustorType: AT - Alloy Tube · FuelType: N - Natural Gas (CH4) · GasOrifice: D2 - 29.0mm · AirOrifice: E8 - 90.0mm · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: S - Standard Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees Контроллер
Цена
213 092 руб.
Вес
41,83 кг
Теги
Burner, ThermJet v2.7

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BIO 80RB-250/235-(6)E
Бренд: Kromschroder
Описание: · Burner size 80 · Cold air · для натурального газа · Length of steel tube as of furnace flange: 250 mm · Distance from furnace flange to front edge of burner head: 235 mm · Burner head identifier 6 · Construction stage E Контроллер
Подробнее
Артикул: BIC 100RFR-0/35-(107)E
Бренд: Kromschroder
Описание: · Burner size 100 · Cold air · для biologically produced methane · Reduced capacity (BIC: select ceramic tube according to brochure inдляmation) · Length of steel tube as of furnace flange: 0 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 107 · Construction stage E Контроллер
Подробнее
Артикул: BCU 460W3P1C1D1100K1E1-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: standard · Valve proving system. TC and POC · High temperature operation · Input function: auxiliary gas · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: fault signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: purge · Function of terminal 6: safety interlocks · Function of terminal 7: high temperature · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Switch-off threshold, burner 1: 5 micro A · Flame simulation check in standby position · High temperature operation: Off · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · Burner application: burner 1 · Function of V5: Off · Auxiliary gas function: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: no function · Proof-of-closure test period: 10 s · Valve proving system: Off · Relief valve (VPS): V2 · Measurement time Vp: 3600 s · Valve opening time 1 (tL1): 2 s · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: ZIO 165KD-200/185-(41)D
Бренд: Kromschroder
Описание: · Burner size 165 · Flat flame · для town gas · Length of steel tube as of furnace flange: 200 mm · Distance from furnace flange to front edge of burner head: 185 mm · Burner head identifier 41 · Construction stage D Контроллер
Подробнее
Артикул: BCU 370QI3FEU0D1B1-3
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring modulating gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EU certified. AGA approved. · European market, EC type tested and certified · Mains voltage: 120 V AC, 50/60 Hz · Electronic ignition, double-pole with neutral conductor · Fan control: 3 A relay · Valve control: three-point step · Flame control: ionization control (continuous or intermittent operation) or UV control (intermittent operation with UVS) · Digital input function: DGmax. monitoring · Fieldbus interface: PROFIBUS DP · Bus control: three-point step · With bottom section · 11 Minimum burner pause time tBP: 0 s · 07 Burner start-up attempts: 1 · 22 Switch-on delay time tE: 0 s · 21 Pre-ignition time tVZ: 1 s · 12 Safety time 1, burner/pilot burner start-up tSA1: 5 s · 13 Flame proving period 1, burner/pilot tFS1: 2 s · 14 Safety time 2, main burner start-up tSA2: 2 s · 15 Flame proving period 2, main burner tFS2: 2 s · 29 Controller enable signal delay time tRF: 10 s · 10 Minimum burner on time tB: 0 s · 09 Safety time during operation tSB: 2 s · 27 V2 during burner operation: On · 08 Behaviour in the event of flame failure during operation: fault lock-out · 02 Burner switch-off threshold: 1 micro A · 17 UVS check (1 x in 24 hours): Off · 16 Operating time in Manual mode: limited to 5 minutes · 30 User-defined password · 04 Air monitoring during pre-purge: On · 05 Air monitoring during operation: On · 23 Min. gas pressure monitoring: On · 24 Digital input function: DGmax. monitoring · 20 Fan run-up time tGV: 0 s · 25 Valve control: On · 31 Bus control activation: On · 32 Bus control limitation: Low position · 06 Pre-purge on each start-up: On · 18 Pre-purge time tPV: 10 s · 19 Post-purge time tPN: 5 s Контроллер
Подробнее
Артикул: BIO 100RB-1550/1385-(109)EB
Бренд: Kromschroder
Описание: · Burner size 100 · Cold air · для натурального газа · Length of steel tube as of furnace flange: 1550 mm · Distance from furnace flange to front edge of burner head: 1385 mm · Burner head identifier 109 · Construction stage E · With purging air bore holes Контроллер
Подробнее