г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: с 9-00 до 21-00
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

TJ 0150-A1AMATNC6E6VAB0 Kromschroder

Артикул
TJ 0150-A1AMATNC6E6VAB0
Дополнительный Артикул
TJ0150A1AMATNC6E6VAB0
Бренд
Kromschroder
Описание
Model: 0150 - 1 500 000 Btu/h (440 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 1 - Furnace Less Than 1750 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: AT - Alloy Tube · FuelType: N - Natural Gas (CH4) · GasOrifice: C6 - 20.0mm · AirOrifice: E6 - 66.0mm · FlameSupervision: V - Extended 3/4" UV Scanner Adapter Only · NozzleMaterial: A - Stainless Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees Контроллер
Цена
197 307 руб.
Вес
20,00 кг
Теги
Burner, ThermJet v2.7

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: TJ 0050-A2AMSCPF3D6FSB2
Бренд: Kromschroder
Описание: Model: 0050 - 500 000 Btu/h (147 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 2 - Furnace 1750 Degrees F to 2500 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: SC - Silicon Carbide · FuelType: P - Propane (C3H8) · GasOrifice: F3 - 8.5mm · AirOrifice: D6 - 42.0mm · FlameSupervision: F - Flame Rod · NozzleMaterial: S - Standard Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 2 - Gas Inlet at 180 Degrees (CW) from Air Inlet at 0 · Degrees Контроллер
Подробнее
Артикул: BCU 460T-5/1LR3-D2B1/1E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · T-product, FM and CSA approved · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · High temperature operation: during intermittent operation with UVS · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 35 UVS check (1 x in 24 hours) · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 15 s Контроллер
Подробнее
Артикул: BCU 480-5/5/1LW1GBS3/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 5-15/100 · Front film in English with additional stickers in D, F, I, NL, E · 3 start-up attempts, pilot burner · 1 start-up attempt, main burner · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее
Артикул: BIC 65RB-550/585-(37)EP
Бренд: Kromschroder
Описание: · Burner size 65 · Cold air · для натурального газа · Length of steel tube as of furnace flange: 550 mm · Distance from furnace flange to front edge of burner head: 585 mm · Burner head identifier 37 · Construction stage E · для pot Разъем Контроллер
Подробнее
Артикул: BCU 460-10/1LW3GBS2B1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 10 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 2 start-up attempts · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: BCU 460-3/1W1GBD3E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 5-15/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер