г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

Контроллеры Kromschroder

Есть вопросы? Напишите нам.

Артикул
Описание
2773Артикул:BCU 580WC1F1U0D1K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator opens with V2 (2nd stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 1 s · 80 Fieldbus communication: with address check Контроллер
2774Артикул:BCU 580WC1F1U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 3 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2775Артикул:BCU 580WC1F1U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during continuous operation with ionization/UVD · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 20 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2776Артикул:BCU 580WC1F2U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для RBW · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with RBW · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: two-stage burner/pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2777Артикул:BCU 580WC1F2U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для RBW · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · 04 Flame control: burner 1: ionization, burner 2: UVS · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during intermittent operation with UVS · 07 Burner/pilot burner start-up attempts: 2 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 40 Capacity control with RBW · 41 Selection of running time: on; для approaching the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator can be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V3 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
2778Артикул:BCU 580WC1F2U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для RBW · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with RBW · 41 Selection of running time: on; для approaching the position для maximum capacity · 42 Running time: 15 s · 48 Air actuator opens with V2 (2nd stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: no address check Контроллер
2779Артикул:BCU 580QC1F3U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: UVS · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during intermittent operation with UVS · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode unlimited · 68 Function of terminal 50:purge with Low signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s Контроллер
2780Артикул:BCU 580WC1F3U0D0K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · 04 Flame control: UVD · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator can be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 20 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2781Артикул:BCU 580WC1F3U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 3 s · 95 Flame proving period 1 tFS1: 0 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
2782Артикул:BCU 580WC1F3U0D0K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · 04 Flame control: burner 1: ionization, burner 2: UVS · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 02 Main burner switch-off threshold: 5 micro A · 07 Burner/pilot burner start-up attempts: 2 · 08 Burner start-up attempts: 3 · 09 Restart: pilot burner · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator closed in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 10 s · 59 Valve opening time V1 (tL1): 3 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 10 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2783Артикул:BCU 580WC1F3U0D1K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 2 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: burner · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator closed in the event of malfunction · 51 Valve proving system: Tightness test beдляe start-up and after shut-down · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 20 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 0 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
2784Артикул:BCU 580WC1F3U0D1K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · 04 Flame control: burner 1: ionization, burner 2: UVS · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during intermittent operation with UVS · 07 Burner/pilot burner start-up attempts: 2 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 30 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator closed in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 30 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode unlimited · 68 Function of terminal 50:purge with Low signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2785Артикул:BCU 580WC1F3U0D1K2-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 3 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner with pilot gas · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s · 80 Fieldbus communication: with address check Контроллер
2786Артикул:BCU 580QC0F1U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 30 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 3 s · 80 Fieldbus communication: with address check Контроллер
2787Артикул:BCU 580QC0F3U0D1K0-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 10 s · 95 Flame proving period 1 tFS1: 0 s · 96 2nd safety time on start-up: 10 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
2788Артикул:BCU 580QC0F2U0D0K1-E
Описание:Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для RBW · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with RBW · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 43 Low fire over-run up to minimum capacity · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
2803Артикул:PFU 760LN
2804Артикул:PFU 760LNK1
2805Артикул:PFU 760LNK2
Описание:19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Air valve control · Mains voltage: 110–120 V AC, 50/60 Hz · Flame control: ionization/UVS · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 3 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 1 start-up attempt · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 30 Air valve can be activated externally · 31 Air valve can be activated externally on start-up · 26 Gas valve V2 opens with operating signal · 36 Low fire over-run time tKN: 0 s · 32 Air valve can be activated in the event of malfunction · 42 Purge with 1 signal (High) Контроллер
2808Артикул:PFU 760LTK2
Описание:19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Air valve control · Mains voltage: 220–240 V AC, 50/60 Hz · Flame control: ionization/UVS · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 10 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 3 start-up attempts · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 26 Gas valve V2 opens with operating signal · 36 Low fire over-run time tKN: 0 s · 32 Air valve can be activated in the event of malfunction · 42 Purge with 1 signal (High) Контроллер
Контроллеры Kromschroder , c 2773 по 2808,заказные номера BCU 580WC1F1U0D1K0-E ... PFU 760LTK2,
классификация Burner control unit Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator opens with V2 (2nd stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 1 s · 80 Fieldbus communication: with address check Контроллер 19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Air valve control · Mains voltage: 220–240 V AC, 50/60 Hz · Flame control: ionization/UVS · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 10 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 3 start-up attempts · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 26 Gas valve V2 opens with operating signal · 36 Low fire over-run time tKN: 0 s · 32 Air valve can be activated in the event of malfunction · 42 Purge with 1 signal (High) Контроллер

Не нашли то, что искали?

Оставьте своё имя и номер телефона, и наш менеджер свяжется с вами в течение 15 минут