Контроллеры Kromschroder
Есть вопросы? Напишите нам.
Каталог товаров
Артикул
Описание
Артикул:BCU 465-3/1LW2GBAE1
Артикул:BCU 465-3/1LW2GBD2ACE1
Артикул:BCU 465-3/1LW2GBD2AE1
Артикул:BCU 465-3/1LW2GBD3A
Артикул:BCU 465-3/1LW2GBD3ACE1
Артикул:BCU 465-3/1LW2GBD3AE1
Артикул:BCU 465-3/1LW2GBPA
Артикул:BCU 465-3/1LW2GBPAC
Артикул:BCU 465-3/1LW2GBPAE1
Артикул:BCU 465-3/1LW2GBPD2AC
Артикул:BCU 465-3/1LW2GBPD2ACE1
Артикул:BCU 465-3/1LW3GBA
Артикул:BCU 465-3/1LW3GBAC
Артикул:BCU 465-3/1LW3GBACE1
Артикул:BCU 465-3/1LW3GBAE1
Артикул:BCU 465-3/1LW3GBD2ACE1
Артикул:BCU 465-3/1LW3GBD3AC
Артикул:BCU 465-3/1LW3GBD3ACE1
Артикул:BCU 465-3/1LW3GBPA
Артикул:BCU 465-3/1LW3GBPAC
Артикул:BCU 465-3/1LW3GBPACE1
Артикул:BCU 465-3/1LW3GBPD2A
Артикул:BCU 465-3/1LW3GBPD2ACE1
Артикул:BCU 465-3/1LW3GBPS3AE1
Артикул:BCU 465-3/1LW3GBS2A
Артикул:BCU 465-3/1LW3GBS2AE1
Артикул:BCU 465-3/1LW3GBS4A
Артикул:BCU 465-3/1LW8GBA
Артикул:BCU 465-3/1LW8GBAC
Артикул:BCU 465-3/1LW8GBACE1
Артикул:BCU 465-3/1LW8GBAE1
Артикул:BCU 465-3/1LW8GBD2ACE1
Артикул:BCU 465-3/1LW8GBD2AE1
Артикул:BCU 465-3/1LW8GBD3A
Артикул:BCU 465-3/1LW8GBD3AE1
Артикул:BCU 465-3/1LW8GBD3S2AE1
Контроллеры Kromschroder , c 649 по 684,заказные номера BCU 465-3/1LW2GBAE1 ... BCU 465-3/1LW8GBD3S2AE1,
классификация Burner control unit, series 400 Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 0 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 20 s Контроллер Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 2 start-up attempts · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 1 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 2 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
классификация Burner control unit, series 400 Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 0 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 20 s Контроллер Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 2 start-up attempts · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 1 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 2 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер