BCU 580QC1F3U0D1K1-E Kromschroder

Артикул
BCU 580QC1F3U0D1K1-E
Дополнительный Артикул
BCU580QC1F3U0D1K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: UVS · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 5 micro A · 06 High temperature operation: during intermittent operation with UVS · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 2 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode unlimited · 68 Function of terminal 50:purge with Low signal · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: with shut-down · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 2 s Контроллер
Цена
122 485 руб.
Вес
0,60 кг
Теги
Burner control unit

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: FGT-SET ECO 2M595-D
Бренд: Kromschroder
Описание: To guide flue gases via the recuperator · для Ecomax 2 · With cast steel ribbed tube recuperator · Burner length: 595 mm · для direct heating Контроллер
Подробнее
Артикул: BCU 480-5/3/1LWGBD3S3/1CB1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 3 start-up attempts, pilot burner · 1 start-up attempt, main burner · With circuit board для signal distribution · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 9 s Контроллер
Подробнее
Артикул: ZIC 165HB-0/35-(18)D
Бренд: Kromschroder
Описание: · Burner size 165 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 0 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 18 · Construction stage D Контроллер
Подробнее
Артикул: ZMI 16G200R
Бренд: Kromschroder
Описание: With one ignition and monitoring electrode для safe ignition of gas burners, with дляced air supply · 16 mm burner size · для LPG · Length: 200 mm · Rp internal thread Контроллер
Подробнее
Артикул: BCU 480-5/3/1L5W8GB
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Low fire over-run time: 5 s · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 3 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve opens with operating signal · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 20 s Контроллер
Подробнее
Артикул: ZT 40B-150/100
Бренд: Kromschroder
Описание: для safeguarding of gas-fired installations of any kind · Protective tube diameter: 40 mm · Natural gas · Protective tube length: 150 · Flame tube length: 100 Контроллер
Подробнее