г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 560WC0F1U0D0K1-E Kromschroder

Артикул
BCU 560WC0F1U0D0K1-E
Дополнительный Артикул
BCU560WC0F1U0D0K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: two-stage burner/pilot burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Цена
72 677 руб.
Вес
0,85 кг
Теги
Burner control unit

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BCU 460-3/1L5W8GBC
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Low fire over-run time: 5 s · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · With circuit board для signal distribution · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 6 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V2 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее
Артикул: RAH 360 , COMPL, NEW GENERATION, POS. 2
Бренд: Kromschroder
Описание: #ИМЯ?
Подробнее
Артикул: BCU 570WC0F2U0K2-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring modulating дляced draught burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Series 570 · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для RBW · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Burner switch-off threshold: 5 micro A · 07 Burner start-up attempts: 1 · 09 Restart: no · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 40 Capacity control with RBW · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow on, maximum capacity · 33 Start-up with pre-purge: yes (depending on P34 Pre-purge time tPV) · 34 Pre-purge time tPV: 5 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 5 s · 38 Air flow monitoring during post-purge: on; control element to maximum capacity · 41 Selection of RBW running time: off; checking the positions для minimum/maximum capacity · 44 Controller enable signal delay time tRF: 0 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 63 Switch-on delay time tE: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 70 Function of terminal 65: AND gating with emergency stop (terminal 46) · 77 User-defined password · 78 Burner application: burner · 93 Pre-ignition time tVZ: 1 s · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s Контроллер
Подробнее
Артикул: AH 400 ,BASIC,NEW GENERATION, POS. 2
Бренд: Kromschroder
Описание: Контроллер
Подробнее
Артикул: TJ 0150-A1AMATNC6E6FSB2
Бренд: Kromschroder
Описание: Customer: X - Engineered Special Order · Model: 0150 - 1 500 000 Btu/h (440 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 1 - Furnace Less Than 1750 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: AT - Alloy Tube · FuelType: N - Natural Gas (CH4) · GasOrifice: C6 - 20.0mm · AirOrifice: E6 - 66.0mm · FlameSupervision: F - Flame Rod · NozzleMaterial: S - Standard Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 2 - Gas Inlet at 180 Degrees (CW) from Air Inlet at 0 · Degrees Контроллер
Подробнее
Артикул: BCU 465-5/1LW8GBD3S3AB1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 3 start-up attempts · Air flow monitoring · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 07 Air flow monitoring during operation · 08 Air flow monitoring, delayed · 39 Pre-ventilation time after safety shut-down: 5 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Restart in the event of burner failure in operation · 20 Minimum burner on time tB: 10 s · 21 Minimum burner pause time tBP: 5 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для single-electrode operation · Minimum time between two start-ups: 20 s Контроллер
Подробнее