BCU 480W1P2C1D0000K2E1-/LM400WF0O0E1- Kromschroder
Артикул
BCU 480W1P2C1D0000K2E1-/LM400WF0O0E1-
Дополнительный Артикул
BCU480W1P2C1D0000K2E1LM400WF0O0E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 5 kV, 15 mA, ED 100 % · Flange plate: M32 · Valve proving system. TC and POC · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with spring дляce terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: none · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 5: start 2 · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Switch-off threshold, burner 1: 5 micro A · Burner 2 switch-off threshold: 5 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Burner 2 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · 2nd safety time on start-up: 3 s · Flame proving period 2 tFS2: 2 s · 78 Burner application: burner 1 and burner 2 · Pilot burner: controlled externally · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): Off · Function of sensor 1: tightness control · Function of sensor 2: no function · Function of sensor 3: no function · Proof-of-closure test period: 10 s · Valve proving system: tightness test beдляe start-up · Relief valve (VPS): V2 · Measurement time Vp: 3600 s · Valve opening time 1 (tL1): 2 s · Fieldbus communication: with address check · Kromschr?der Safety Link: Off Контроллер
Цена
165 880 руб.
Вес
5,66 кг
Теги
Burner control unit, series 400
Узнайте актуальную цену данного товара
Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут