BCU 480Q8P7C2D1000K2E1-/LM400QF1O1E1- Kromschroder

Артикул
BCU 480Q8P7C2D1000K2E1-/LM400QF1O1E1-
Дополнительный Артикул
BCU480Q8P7C2D1000K2E1LM400QF1O1E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 120 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 33 % · Flange plate: conduit · Valve proving system. POC · High temperature operation · Input function: none · Pressure switch: none · Connection plugs with spring дляce terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 120 V AC, 50/60 Hz · Air actuator: with IC 40 interface · Optional output: not fail-safe · Energy supply: via L1 · Flame control: burner 1: UVS, burner 2: UVC · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: start 2 · Function of terminal 6: high temperature · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Function of terminal 40: air actuator R1 · Function of terminal 41: air actuator R2 · Switch-off threshold, burner 1: 5 micro A · Burner 2 switch-off threshold: 5 micro A · Flame simulation check in standby position · High temperature operation: Off · Burner 1 start-up attempts: 1 · Burner 2 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · 2nd safety time on start-up: 3 s · Flame proving period 2 tFS2: 2 s · Burner application: burner 1 · Pilot burner: controlled externally · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: no function · Proof-of-closure test period: 10 s · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Цена
176 176 руб.
Вес
5,66 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BCU 480W3P6C1D0000K1E1-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: PROFIBUS · Valve proving system. TC and POC · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: start 2 · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Switch-off threshold, burner 1: 2 micro A · Burner 2 switch-off threshold: 2 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Burner 2 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 0 s · 2nd safety time on start-up: 3 s · Flame proving period 2 tFS2: 0 s · 78 Burner application: burner 1 and burner 2 · Pilot burner: controlled externally · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: can be activated externally · Safety time during operation: 1 s · Minimum burner on time tB: 0 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: tightness control · Proof-of-closure test period: 10 s · Valve proving system: tightness test beдляe start-up · Relief valve (VPS): V2 · Measurement time Vp: 5 s · Valve opening time 1 (tL1): 2 s · Fieldbus communication: no address check · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: IFD 258-3/1P
Бренд: Kromschroder
Описание: Ignites and monitors gas burners, Для непрерывного контроля operation with ionization control, adjustable cut-off point, display для indicating program status and flame signal intensity, IP 54, EU certified, FM and CSA approved · Series 200 · Ionization or UV control · Immediate fault lock-out or restart in the event of flame failure, switchable · Safety time on start-up: 3 s · Safety time during operation: 1 s · Mains voltage: 100 V AC, 50/60 Hz Контроллер
Подробнее
Артикул: BCU 370QFEU1D3
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring modulating gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EU certified. AGA approved. · European market, EC type tested and certified · Mains voltage: 120 V AC, 50/60 Hz · Fan control: 3 A relay · Valve control: three-point step · Flame control: UV control (continuous operation with UVD) · Digital input function: integrated tightness control · With bottom section · 11 Minimum burner pause time tBP: 0 s · 07 Burner start-up attempts: 1 · 22 Switch-on delay time tE: 0 s · 21 Pre-ignition time tVZ: 1 s · 12 Safety time 1, burner/pilot burner start-up tSA1: 3 s · 13 Flame proving period 1, burner/pilot tFS1: 2 s · 14 Safety time 2, main burner start-up tSA2: 3 s · 15 Flame proving period 2, main burner tFS2: 2 s · 29 Controller enable signal delay time tRF: 0 s · 10 Minimum burner on time tB: 0 s · 09 Safety time during operation tSB: 1 s · 27 V2 during burner operation: Off · 08 Behaviour in the event of flame failure during operation: fault lock-out · 17 UVS check (1 x in 24 hours): Off · 16 Operating time in Manual mode: limited to 5 minutes · 30 User-defined password · 04 Air monitoring during pre-purge: On · 05 Air monitoring during operation: On · 23 Min. gas pressure monitoring: On · 24 Digital input function: DGmax. monitoring · 26 TC test period tP: 10 s · 20 Fan run-up time tGV: 2 s · 25 Valve control: On · 06 Pre-purge on each start-up: On · 18 Pre-purge time tPV: 30 s · 19 Post-purge time tPN: 0 s Контроллер
Подробнее
Артикул: ZIC 165HB-0/235-(18)D
Бренд: Kromschroder
Описание: · Burner size 165 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 0 mm · Distance from furnace flange to front edge of burner head: 235 mm · Burner head identifier 18 · Construction stage D Контроллер
Подробнее
Артикул: ECOMAX 1C545-SB/R-(31)B
Бренд: Kromschroder
Описание: для heating of furnace systems · Burner size 1, rated capacity: 36 kW · With ceramic burled tube recuperator made of SiSiC · Recuperator length: 545 mm · With staged combustion · для натурального газа · для radiant tube heating without eductor · Burner head identifier 31 · Construction stage B Контроллер
Подробнее
Артикул: BCU 460-3/1W8GBCB1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · With circuit board для signal distribution · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер