г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 480-3/3/1LW8GB Kromschroder

Артикул
BCU 480-3/3/1LW8GB
Дополнительный Артикул
BCU480331LW8GB
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 3 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Цена
157 509 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: PFU 760LNUK2
Бренд: Kromschroder
Описание: 19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Air valve control · Mains voltage: 110–120 V AC, 50/60 Hz · Flame control: UVD 1 (UV continuous operation) · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 3 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 1 start-up attempt · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 26 Gas valve V2 opens with operating signal · 36 Low fire over-run time tKN: 0 s · 32 Air valve can be activated in the event of malfunction · 42 Purge with 1 signal (High) Контроллер
Подробнее
Артикул: BIO 50HB-1100/1035-(37)D
Бренд: Kromschroder
Описание: · Burner size 50 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 1100 mm · Distance from furnace flange to front edge of burner head: 1035 mm · Burner head identifier 37 · Construction stage D Контроллер
Подробнее
Артикул: BCU 560WC1F1U0D0K0-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · No connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: on; для approaching the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator can be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 72 Function of terminal 67: AND gating with emergency stop (terminal 46) · 73 Function of terminal 68: AND gating with emergency stop (terminal 46) · 77 User-defined password · 78 Burner application: burner with pilot gas · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: BCU 460-5/1WGBS4
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Front film in English with additional stickers in D, F, I, NL, E · 4 start-up attempts · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 9 s Контроллер
Подробнее
Артикул: BCU 480W3P2C0D0000K1E0-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: M32 · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via safety interlocks · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: start 2 · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 2 micro A · Burner 2 switch-off threshold: 2 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 3 · Burner 2 start-up attempts: 3 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 10 s · Flame proving period 1 tFS1: 2 s · 2nd safety time on start-up: 5 s · Flame proving period 2 tFS2: 2 s · 78 Burner application: burner 1 and burner 2 · Pilot burner: controlled externally · Restart: max. 5 для burner 1 in 15 min. · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 0 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: FLUP 1/2-50D-M331-C-S
Бренд: Kromschroder
Описание: To discharge the flue gas для indirect heating · для Ecomax 1/2 · DN 50 · Pipe connector · Installation height M = 331 mm · Measuring port with sealing clip · Standard dimensions Контроллер
Подробнее