BCU 480-10/5/2LW3GBU Kromschroder

Артикул
BCU 480-10/5/2LW3GBU
Дополнительный Артикул
BCU4801052LW3GBU
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 5 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · Configured and prepared для UVD 1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Цена
163 812 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BIOW 65KB-250/235-(46)E
Бренд: Kromschroder
Описание: · Burner size 65 · Flat flame · для натурального газа · Length of steel tube as of furnace flange: 250 mm · Distance from furnace flange to front edge of burner head: 235 mm · Burner head identifier 46 · Construction stage E Контроллер
Подробнее
Артикул: BIC 140RM-100/135-(48)E
Бренд: Kromschroder
Описание: · Burner size 140 · Cold air · для propane, propane/butane, butane (with mixer) · Length of steel tube as of furnace flange: 100 mm · Distance from furnace flange to front edge of burner head: 135 mm · Burner head identifier 48 · Construction stage E Контроллер
Подробнее
Артикул: ECOMAX 3M545-SL/D-(39)B
Бренд: Kromschroder
Описание: для heating of furnace systems · Burner size 3, rated capacity: 100 kW · With cast steel ribbed tube recuperator · Recuperator length: 545 mm · With staged combustion · для LCV gas · для direct heating with eductor · Burner head identifier 39 · Construction stage B Контроллер
Подробнее
Артикул: BIO 100HM-400/335-(67)E
Бренд: Kromschroder
Описание: · Burner size 100 · Hot air/high furnace temperature · для propane, propane/butane, butane (with mixer) · Length of steel tube as of furnace flange: 400 mm · Distance from furnace flange to front edge of burner head: 335 mm · Burner head identifier 67 · Construction stage E Контроллер
Подробнее
Артикул: BCU 480W2P6C1D0000K1E1-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 19 % · Flange plate: PROFIBUS · Valve proving system. TC and POC · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: start 2 · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Switch-off threshold, burner 1: 5 micro A · Burner 2 switch-off threshold: 5 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Burner 2 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · 2nd safety time on start-up: 3 s · Flame proving period 2 tFS2: 2 s · 78 Burner application: burner 1 and burner 2 · Pilot burner: controlled externally · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: no function · Proof-of-closure test period: 0 s · Valve proving system: tightness test beдляe start-up · Relief valve (VPS): V2 · Measurement time Vp: 5 s · Valve opening time 1 (tL1): 2 s · Fieldbus communication: with address check · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: ECOMAX 0C556-SB/R-(31)B
Бренд: Kromschroder
Описание: для heating of furnace systems · Burner size 0, rated capacity: 25 kW · With ceramic burled tube recuperator made of SiSiC · Recuperator length: 556 mm · With staged combustion · для натурального газа · для radiant tube heating without eductor · Burner head identifier 31 · Construction stage B Контроллер
Подробнее