BCU 480-10/5/1LW2GBD3S2/4C Kromschroder

Артикул
BCU 480-10/5/1LW2GBD3S2/4C
Дополнительный Артикул
BCU4801051LW2GBD3S24C
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 2 start-up attempts, pilot burner · 4 start-up attempts, main burner · With circuit board для signal distribution · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 5 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 60 s Контроллер
Цена
175 318 руб.
Вес
4,60 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: TJ 0075-A2AHSCNF5D9XAN0
Бренд: Kromschroder
Описание: Customer: # - Standard Product Options · Model: 0075 - 750 000 Btu/h (220 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 2 - Furnace 1750 Degrees F to 2500 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: H - High Velocity Outlet · CombustorType: SC - Silicon Carbide · FuelType: N - Natural Gas (CH4) · GasOrifice: F5 - 13.5mm · AirOrifice: D9 - 49.0mm · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: A - Stainless Nozzle · PipingConnection: N – NPT · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees · Vorschlag Standard Price [WINMAN-Gouda]: Контроллер
Подробнее
Артикул: TJ 0300-A2AMBHND2E8XAB0
Бренд: Kromschroder
Описание: Model: 0300 - 3 000 000 Btu/h (879 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 2 - Furnace 1750 Degrees F to 2500 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: BH - Block and Holder · FuelType: N - Natural Gas (CH4) · GasOrifice: D2 - 29.0mm · AirOrifice: E8 - 90.0mm · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: A - Stainless Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees Контроллер
Подробнее
Артикул: BCU 480W3P1C1D1000K1E1-/LM400WF1O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: standard · Valve proving system. TC and POC · High temperature operation · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with IC 40 interface · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 2 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: start 2 · Function of terminal 6: high temperature · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Function of terminal 40: air actuator R1 · Function of terminal 41: air actuator R2 · Switch-off threshold, burner 1: 5 micro A · Burner 2 switch-off threshold: 5 micro A · Flame simulation check in standby position · High temperature operation: continuous operation · Burner 1 start-up attempts: 3 · Burner 2 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 5 s · Flame proving period 1 tFS1: 2 s · 2nd safety time on start-up: 3 s · Flame proving period 2 tFS2: 2 s · Burner application: burner 1 · Pilot burner: controlled externally · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via non-fail-safe bus or terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: no function · Proof-of-closure test period: 10 s · Valve proving system: tightness test beдляe start-up · Relief valve (VPS): V2 · Measurement time Vp: 60 s · Valve opening time 1 (tL1): 2 s · Fieldbus communication: with address check · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: ZMI 25G1300R
Бренд: Kromschroder
Описание: With one ignition and monitoring electrode для safe ignition of gas burners, with дляced air supply · 25 mm burner size · для LPG · Length: 1300 mm · Rp internal thread Контроллер
Подробнее
Артикул: PFU 760TDUK2
Бренд: Kromschroder
Описание: 19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Mains voltage: 220–240 V AC, 50/60 Hz · With high temperature mode · Flame control: UVD 1 (UV continuous operation) · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 3 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 1 start-up attempt · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 31 Air valve cannot be activated externally on start-up Контроллер
Подробнее
Артикул: BCU 465W3P3C0D0010K1E1-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: 16-pin industrial plug connector · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch для air · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 35: safety interlocks · Function of terminal 36: sensor 1 · Function of terminal 37: sensor 2 · Function of terminal 38: sensor 3 · Switch-off threshold, burner 1: 5 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · Burner application: burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Delayed low air pressure protection: On · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Pre-purge time tPV: 6000 s · Pre-ventilation time tVL: 0 s · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Function of sensor 1: no function · Function of sensor 2: no function · Function of sensor 3: no function · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Подробнее