г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 465T-5/2LR3-OE1 Kromschroder

Артикул
BCU 465T-5/2LR3-OE1
Дополнительный Артикул
BCU465T52LR3OE1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · T-product, FM and CSA approved · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · With POC check · Voltage для valves and ignition transдляmer via L1 · 09 Position indicator feedback · 39 Pre-ventilation time after safety shut-down: 0 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 5 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 15 s Контроллер
Цена
150 227 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BCU 460W3P6C0D1000K1E1-/LM400WF0O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: PROFIBUS · Valve proving system. none · High temperature operation · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: none · Optional output: none · Energy supply: via L1 · Flame control: UVC · Function of contact 80, 81/82: fault signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 6: high temperature · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 5 micro A · Flame simulation check in standby position · High temperature operation: continuous operation · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 0 s · Burner application: two-stage burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Safety time during operation: 1 s · Minimum burner on time tB: 3 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): Off · Fieldbus communication: no address check · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: BCU 560QC1F1U0D1K1-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · With valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · High temperature operation · Screw connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 20 · 42 Running time: 250 s · 44 Controller enable signal delay time tRF: 0 s · 48 Controller enable following operating signal or in standby · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 51 Valve proving system: tightness test beдляe start-up · 52 Relief valve (VPS): V2 · 56 Measurement time Vp: 600 s · 59 Valve opening time V1 (tL1): 2 s · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: BCU 480T-10/3/2LR3-E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · T-product, FM and CSA approved · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: TJ 0200-D5AMBHND1XXXAB0
Бренд: Kromschroder
Описание: Model: 0200 - 2 000 000 Btu/h (586 kW) · PreheatTemperature: D - Preheat 700 Degrees F to 1000 Degrees F · FurnaceTemperature: 5 - Furnace 2200 Degrees F to 2800 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: BH - Block and Holder · FuelType: N - Natural Gas (CH4) · GasOrifice: D1 - 24.0mm · AirOrifice: XX - No Air Orifice · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: A - Stainless Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees Контроллер
Подробнее
Артикул: ECOMAX 4M695-SB/E-(31)X-AWZ
Бренд: Kromschroder
Описание: для heating of furnace systems · Burner size 4, rated capacity: 180 kW · With cast steel ribbed tube recuperator · Recuperator length: 695 mm · With staged combustion · для натурального газа · Burner with customized orifices · Burner head identifier 31 · Construction stage X · The following features differ from the standard version: · Electrode made of Kanthal APM · Air connection without intermediate flange · Special version Контроллер
Подробнее
Артикул: BCU 370QI1FEU1D1B1-3
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring modulating gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EU certified. AGA approved. · European market, EC type tested and certified · Mains voltage: 120 V AC, 50/60 Hz · Electronic ignition, single-pole · Fan control: 3 A relay · Valve control: three-point step · Flame control: UV control (continuous operation with UVD) · Digital input function: DGmax. monitoring · Fieldbus interface: PROFIBUS DP · Bus control: three-point step · With bottom section · 11 Minimum burner pause time tBP: 0 s · 07 Burner start-up attempts: 2 · 22 Switch-on delay time tE: 0 s · 21 Pre-ignition time tVZ: 0 s · 12 Safety time 1, burner/pilot burner start-up tSA1: 3 s · 13 Flame proving period 1, burner/pilot tFS1: 2 s · 14 Safety time 2, main burner start-up tSA2: 2 s · 15 Flame proving period 2, main burner tFS2: 2 s · 29 Controller enable signal delay time tRF: 0 s · 10 Minimum burner on time tB: 0 s · 09 Safety time during operation tSB: 1 s · 27 V2 during burner operation: On · 08 Behaviour in the event of flame failure during operation: fault lock-out · 17 UVS check (1 x in 24 hours): Off · 16 Operating time in Manual mode: limited to 5 minutes · 30 User-defined password · 04 Air monitoring during pre-purge: On · 05 Air monitoring during operation: On · 23 Min. gas pressure monitoring: On · 24 Digital input function: DGmax. monitoring · 20 Fan run-up time tGV: 0 s · 25 Valve control: On · 31 Bus control activation: On · 32 Bus control limitation: Closed position · 06 Pre-purge on each start-up: On · 18 Pre-purge time tPV: 250 s · 19 Post-purge time tPN: 10 s Контроллер
Подробнее