г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 465-3/1LW8GBPS2A Kromschroder

Артикул
BCU 465-3/1LW8GBPS2A
Дополнительный Артикул
BCU46531LW8GBPS2A
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · 2 start-up attempts · Air flow monitoring · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 08 Air flow monitoring, delayed · 39 Pre-ventilation time after safety shut-down: 4 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 8 s · 21 Minimum burner pause time tBP: 4 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve can be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 35 UVS check (1 x in 24 hours) · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для single-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Цена
159 533 руб.
Вес
5,30 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: RAH 160, basic,new generation Position 1
Бренд: Kromschroder
Описание: Контроллер
Подробнее
Артикул: BCU 480-10/3/1LW3GBD2
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during intermittent operation with UVS · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: BCU 465W2P2C0D0000K1E1-/LM400WF3O0E1-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 19 % · Flange plate: M32 · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via L1 · Flame control: UVS · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 5 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · Burner application: burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Pre-purge time tPV: 6000 s · Pre-ventilation time tVL: 0 s · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: BCU 480-5/10/1LW2GBPD3S4/2U
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 10 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · High temperature operation: during continuous operation with ionization/UVD · 4 start-up attempts, pilot burner · 2 start-up attempts, main burner · Configured and prepared для UVD 1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Restart in the event of main burner failure in operation · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: TJ 0075-D4AMSCNF5XXXAB2
Бренд: Kromschroder
Описание: Model: 0075 - 750 000 Btu/h (220 kW) · PreheatTemperature: D - Preheat 700 Degrees F to 1000 Degrees F · FurnaceTemperature: 4 - Furnace 1750 Degrees F to 2200 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: SC - Silicon Carbide · FuelType: N - Natural Gas (CH4) · GasOrifice: F5 - 13.5mm · AirOrifice: XX - No Air Orifice · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: A - Stainless Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 2 - Gas Inlet at 180 Degrees (CW) from Air Inlet at 0 · Degrees Контроллер
Подробнее
Артикул: BIO 140RML-50/35-(49)E
Бренд: Kromschroder
Описание: · Burner size 140 · Cold air · для propane, propane/butane, butane (with mixer) · Torch · Length of steel tube as of furnace flange: 50 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 49 · Construction stage E Контроллер
Подробнее