г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 460W2P6C0D0000K1E1-/LM400WF0O0E1- Kromschroder

Артикул
BCU 460W2P6C0D0000K1E1-/LM400WF0O0E1-
Дополнительный Артикул
BCU460W2P6C0D0000K1E1LM400WF0O0E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 19 % · Flange plate: PROFIBUS · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: none · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 2 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 0 s · Burner application: burner 1 · Function of V5: Off · Restart: burner 1 · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Safety time during operation: 1 s · Minimum burner on time tB: 0 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): Off · Fieldbus communication: no address check · Kromschr?der Safety Link: Off Контроллер
Цена
117 337 руб.
Вес
5,03 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: TJ 0075-A2AMSCNF5D9XSB2
Бренд: Kromschroder
Описание: Model: 0075 - 750 000 Btu/h (220 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 2 - Furnace 1750 Degrees F to 2500 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: SC - Silicon Carbide · FuelType: N - Natural Gas (CH4) · GasOrifice: F5 - 13.5mm · AirOrifice: D9 - 49.0mm · FlameSupervision: X - 1/2" UV Scanner Adapter Only · NozzleMaterial: S - Standard Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 2 - Gas Inlet at 180 Degrees (CW) from Air Inlet at 0 · Degrees Контроллер
Подробнее
Артикул: BCU 580WC0F1U0D0K2-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Version для pilot and main burners · EU certified, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 230 V AC, 50/60 Hz · No valve proving system · Modulating capacity control with interface для actuator IC · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 02 Main burner switch-off threshold: 2 micro A · 07 Burner/pilot burner start-up attempts: 1 · 08 Burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with IC 40 · 41 Selection of running time: off; checking the positions для minimum/maximum capacity · 42 Running time: 250 s · 48 Air actuator can be activated externally · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 0 s · 62 Minimum pause time tBP: 0 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 69 Function of terminal 51: IC 40/RBW max. capacity feedback · 77 User-defined password · 78 Burner application: burner and pilot burner · 79 Pilot burner: continuous operation · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 0 s · 96 2nd safety time on start-up: 3 s · 97 Flame proving period 2 tFS2: 0 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: PFU 760LNUK2
Бренд: Kromschroder
Описание: 19'' rack-mounted модуль, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. FM approved, certified для systems up to SIL 3 (compliant with PL e). · European market, complies with EC Low Voltage Directive · Air valve control · Mains voltage: 110–120 V AC, 50/60 Hz · Flame control: UVD 1 (UV continuous operation) · Replacement для PFU 778/PFU 798 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 15 Flame simulation check in start-up position/standby · 21 Minimum burner pause time tBP: 0 s · Safety time on start-up tSA: 3 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 20 Minimum burner on time tB: 0 s · 1 start-up attempt · Safety time during operation tSB: 1 s · 12 Fault lock-out in the event of burner failure in operation · 34 Burner on time in Manual mode limited to 5 minutes · 50 User-defined password · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 26 Gas valve V2 opens with operating signal · 36 Low fire over-run time tKN: 0 s · 32 Air valve can be activated in the event of malfunction · 42 Purge with 1 signal (High) Контроллер
Подробнее
Артикул: BCU 480-5/5/1LR2GBS2/1E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · 2 start-up attempts, pilot burner · 1 start-up attempt, main burner · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: BIC 100RB-250/285-(109)FR
Бренд: Kromschroder
Описание: · Burner size 100 · Cold air · для натурального газа · Length of steel tube as of furnace flange: 250 mm · Distance from furnace flange to front edge of burner head: 285 mm · Burner head identifier 109 · Construction stage F · для annular excess air burner Разъем Контроллер
Подробнее
Артикул: BCU 465T-10/2LR8-D2OB1/1E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · T-product, FM and CSA approved · Safety time on start-up tSA: 10 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · High temperature operation: during intermittent operation with UVS · With POC check · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · Voltage для valves and ignition transдляmer via L1 · 09 Position indicator feedback · 39 Pre-ventilation time after safety shut-down: 0 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее