BCU 460W2P2C0D1100K1E1-/LM400WF1O0E1- Kromschroder
Артикул
BCU 460W2P2C0D1100K1E1-/LM400WF1O0E1-
Дополнительный Артикул
BCU460W2P2C0D1100K1E1LM400WF1O0E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 19 % · Flange plate: M32 · Valve proving system. none · High temperature operation · Input function: auxiliary gas · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via L1 · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with IC 40 interface · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 5: auxiliary gas · Function of terminal 6: high temperature · Function of terminal 35: safety interlocks · Function of terminal 40: air actuator R1 · Function of terminal 41: air actuator R2 · Switch-off threshold, burner 1: 2 micro A · Flame simulation check in standby position · High temperature operation: continuous operation · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · Burner application: two-stage burner 1 · Function of V5: Off · Auxiliary gas function: operation · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: off; checking the positions для minimum/maximum capacity · Running time: 25 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Fieldbus communication: no address check · Kromschr?der Safety Link: Off Контроллер
Цена
156 805 руб.
Вес
5,03 кг
Теги
Burner control unit, series 400
Узнайте актуальную цену данного товара
Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут