г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 460W2P1C0D0000K1E0-/LM400WF0O0E1- Kromschroder

Артикул
BCU 460W2P1C0D0000K1E0-/LM400WF0O0E1-
Дополнительный Артикул
BCU460W2P1C0D0000K1E0LM400WF0O0E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 20 mA, ED 19 % · Flange plate: standard · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via safety interlocks · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: none · Optional output: none · Energy supply: via L1 · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 2 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 2 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 5 s · Flame proving period 1 tFS1: 0 s · Burner application: two-stage burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Safety time during operation: 1 s · Minimum burner on time tB: 5 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): Off · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Цена
116 182 руб.
Вес
5,03 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BCU 460-5/1WGB
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Front film in English with additional stickers in D, F, I, NL, E · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 5 s · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 9 s Контроллер
Подробнее
Артикул: BCU 465-3/1LW3GBS2AE1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 2 start-up attempts · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 0 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее
Артикул: BCU 460-5/1W1GBD3S2
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 5-15/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 2 start-up attempts · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее
Артикул: BCU 560QC0F3U0D0K2-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. · Standard version · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Mains voltage: 120 V AC, 50/60 Hz · No valve proving system · Air valve control · Flammen?berwachung mit Ionisations- oder UV-Signal · Spring дляce connection terminals · Individual packaging · Flame control: ionization · 01 Switch-off threshold, burner/pilot burner: 5 micro A · 07 Burner/pilot burner start-up attempts: 1 · 09 Restart: no · Safety time during operation: 1 s · 40 Capacity control with air valve · 42 Running time: 1 s · 48 Air actuator opens with V1 (1st stage) · 49 Air actuator cannot be activated externally on start-up · 50 Air actuator can be activated in the event of malfunction · 52 Relief valve (VPS): V2 · 61 Minimum burner on time tB: 8 s · 62 Minimum pause time tBP: 4 s · 67 Operating time in Manual mode limited to 5 min. · 68 Function of terminal 50:purge with High signal · 77 User-defined password · 78 Burner application: burner · 94 1st safety time on start-up: 5 s · 95 Flame proving period 1 tFS1: 2 s · 80 Fieldbus communication: with address check Контроллер
Подробнее
Артикул: BIC 65HM-150/285-(72A)ER
Бренд: Kromschroder
Описание: · Burner size 65 · Hot air/high furnace temperature · для propane, propane/butane, butane (with mixer) · Length of steel tube as of furnace flange: 150 mm · Distance from furnace flange to front edge of burner head: 285 mm · Burner head identifier 72 · Burner head: heat-resistant · Construction stage E · для annular excess air burner Разъем Контроллер
Подробнее
Артикул: BCU 465-5/2LW3GBPD2S4AC
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · High temperature operation: during intermittent operation with UVS · 4 start-up attempts · Air flow monitoring · With circuit board для signal distribution · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 15 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 5 s · 30 Air valve opens with V1 · 31 Air valve can be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 5 s · 38 Post-ventilation time: 1 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 15 s Контроллер
Подробнее