г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 460-5/2LR3GB Kromschroder

Артикул
BCU 460-5/2LR3GB
Дополнительный Артикул
BCU46052LR3GB
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve can be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 15 s Контроллер
Цена
136 752 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BIC 100HB-300/335-(37E)ER
Бренд: Kromschroder
Описание: · Burner size 100 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 300 mm · Distance from furnace flange to front edge of burner head: 335 mm · Burner head identifier 37 · Burner head: heat-resistant, with purged electrodes · Construction stage E · для annular excess air burner Разъем Контроллер
Подробнее
Артикул: IFD 258-5/2W
Бренд: Kromschroder
Описание: Ignites and monitors gas burners, Для непрерывного контроля operation with ionization control, adjustable cut-off point, display для indicating program status and flame signal intensity, IP 54, EU certified, FM and CSA approved · Series 200 · Ionization or UV control · Immediate fault lock-out or restart in the event of flame failure, switchable · Safety time on start-up: 5 s · Safety time during operation: 2 s · Mains voltage: 230 V AC, 50/60 Hz Контроллер
Подробнее
Артикул: BIO 80RB-150/135-(6)E
Бренд: Kromschroder
Описание: · Burner size 80 · Cold air · для натурального газа · Length of steel tube as of furnace flange: 150 mm · Distance from furnace flange to front edge of burner head: 135 mm · Burner head identifier 6 · Construction stage E Контроллер
Подробнее
Артикул: BCU 480-5/3/1LW1GBS2/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 5-15/100 · Front film in English with additional stickers in D, F, I, NL, E · 2 start-up attempts, pilot burner · 1 start-up attempt, main burner · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее
Артикул: TJ 0050-A1AMATPF3D6FSB0
Бренд: Kromschroder
Описание: Model: 0050 - 500 000 Btu/h (147 kW) · PreheatTemperature: A - No Preheat Ambient · FurnaceTemperature: 1 - Furnace Less Than 1750 Degrees F · FiringPosition: A - Horizontal or Vertical Up · BurnerStyle: M - Medium Velocity Outlet · CombustorType: AT - Alloy Tube · FuelType: P - Propane (C3H8) · GasOrifice: F3 - 8.5mm · AirOrifice: D6 - 42.0mm · FlameSupervision: F - Flame Rod · NozzleMaterial: S - Standard Nozzle · PipingConnection: B - BSP (Rc) · GasOrientation: 0 - Gas Inlet at 0 Degrees with Air Inlet at 0 Degrees Контроллер
Подробнее
Артикул: BCU 465-3/2LR8GBPAE1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 2 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · Integrated industrial chassis plug, 16-pin · Air flow monitoring · Voltage для valves and ignition transдляmer via L1 · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 08 Air flow monitoring, delayed · 39 Pre-ventilation time after safety shut-down: 7 s · 40 Pre-ventilation для restart/start-up attempts · 41 Pre-ventilation after reset · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 8 s · 21 Minimum burner pause time tBP: 8 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 0 s · Pre-wired для single-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее