г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 460-3/1LW8GBD2B1/2E1 Kromschroder

Артикул
BCU 460-3/1LW8GBD2B1/2E1
Дополнительный Артикул
BCU46031LW8GBD2B12E1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during intermittent operation with UVS · PROFIBUS DP interface · Integrated standard PROFIBUS DP chassis socket, 9-pin · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 4 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: 8 s · 21 Minimum burner pause time tBP: 4 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve can be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Цена
180 345 руб.
Вес
5,10 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: BCU 480-10/5/1LW8GBD3B1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 10 s · 2nd safety time on start-up (main burner) tSA2: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Restart in the event of pilot burner failure in operation · 13 Restart in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Pilot burner is switched off · 20 Minimum burner on time tB: 7 s · 21 Minimum burner pause time tBP: 7 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve closed in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: BIO 100KB-50/35-(41)E
Бренд: Kromschroder
Описание: · Burner size 100 · Flat flame · для натурального газа · Length of steel tube as of furnace flange: 50 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 41 · Construction stage E Контроллер
Подробнее
Артикул: BCU 370WI2FEU0D1B1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring modulating gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EU certified. AGA approved. · European market, EC type tested and certified · Mains voltage: 230 V AC, 50/60 Hz · Electronic ignition, double-pole · Fan control: 3 A relay · Valve control: three-point step · Flame control: ionization control (continuous or intermittent operation) or UV control (intermittent operation with UVS) · Digital input function: DGmax. monitoring · Fieldbus interface: PROFIBUS DP · With bottom section · 11 Minimum burner pause time tBP: 0 s · 07 Burner start-up attempts: 1 · 22 Switch-on delay time tE: 0 s · 21 Pre-ignition time tVZ: 1 s · 12 Safety time 1, burner/pilot burner start-up tSA1: 5 s · 13 Flame proving period 1, burner/pilot tFS1: 2 s · 14 Safety time 2, main burner start-up tSA2: 3 s · 15 Flame proving period 2, main burner tFS2: 2 s · 29 Controller enable signal delay time tRF: 0 s · 10 Minimum burner on time tB: 0 s · 09 Safety time during operation tSB: 1 s · 27 V2 during burner operation: Off · 08 Behaviour in the event of flame failure during operation: fault lock-out · 02 Burner switch-off threshold: 1 micro A · 17 UVS check (1 x in 24 hours): Off · 16 Operating time in Manual mode: limited to 5 minutes · 30 User-defined password · 04 Air monitoring during pre-purge: Off · 05 Air monitoring during operation: Off · 23 Min. gas pressure monitoring: Off · 24 Digital input function: DGmax. monitoring · 20 Fan run-up time tGV: 2 s · 25 Valve control: On · 06 Pre-purge on each start-up: On · 18 Pre-purge time tPV: 30 s · 19 Post-purge time tPN: 0 s Контроллер
Подробнее
Артикул: BIO 125HB-500/435-(2)E
Бренд: Kromschroder
Описание: · Burner size 125 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 500 mm · Distance from furnace flange to front edge of burner head: 435 mm · Burner head identifier 2 · Construction stage E Контроллер
Подробнее
Артикул: ZIC 165HB-900/935-(18)DB
Бренд: Kromschroder
Описание: · Burner size 165 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 900 mm · Distance from furnace flange to front edge of burner head: 935 mm · Burner head identifier 18 · Construction stage D · With purging air bore holes Контроллер
Подробнее
Артикул: BCU 480-3/3/1LW3GBD3S2/1B1/1E1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 3 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during continuous operation with ionization/UVD · 2 start-up attempts, pilot burner · 1 start-up attempt, main burner · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее