г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

BCU 460-10/1WGBD2UE1 Kromschroder

Артикул
BCU 460-10/1WGBD2UE1
Дополнительный Артикул
BCU460101WGBD2UE1
Бренд
Kromschroder
Описание
Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 10 s · Safety time during operation tSB: 1 s · Mains voltage: 230 V AC, 50/60 Hz · Front film in English with additional stickers in D, F, I, NL, E · High temperature operation: during intermittent operation with UVS · Configured and prepared для UVD 1 · Voltage для valves and ignition transдляmer via L1 · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 9 s Контроллер
Цена
133 397 руб.
Вес
3,00 кг
Теги
Burner control unit, series 400

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: ZIO 200KBL-50/35-(38)D
Бренд: Kromschroder
Описание: · Burner size 200 · Flat flame · для натурального газа · Torch · Length of steel tube as of furnace flange: 50 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 38 · Construction stage D Контроллер
Подробнее
Артикул: BCU 460W3P6C0D0000K1E0-/LM400WF3O0E0-
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, FM and EAC approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer: 8 kV, 12 mA, ED 100 % · Flange plate: PROFIBUS · Valve proving system. none · High temperature operation: none · Input function: none · Pressure switch: none · Connection plugs with screw terminals · Individual packaging · Energy supply: via safety interlocks · Power модуль · Series 400 · Mains voltage: 230 V AC, 50/60 Hz · Air actuator: with air valve control · Optional output: none · Energy supply: via safety interlocks · Flame control: ionization · Function of contact 80, 81/82: fault signal · Function of contact 90, 91/92: ready signal · Function of contact 95/96: burner 1 operating signal · Function of contact 95/97: burner 1 operating signal · Function of contact 85/86, 87: air signal · Function of terminal 1: start 1 · Function of terminal 2: reset · Function of terminal 3: purge · Function of terminal 4: air · Function of terminal 35: safety interlocks · Switch-off threshold, burner 1: 5 micro A · Flame simulation check in standby position · Burner 1 start-up attempts: 1 · Pre-ignition time tVZ: 0 s · 1st safety time on start-up: 3 s · Flame proving period 1 tFS1: 2 s · Burner application: burner 1 · Function of V5: Off · Restart: no · Combustion mode: Flame mode · Over-run: Off · Over-run time: 0 s · Air actuator control: opens on external activation · Active cooling outputs: air actuator · Selection of running time: on; для approaching the positions для minimum/maximum capacity · Running time: 1 s · Air actuator on start-up: cannot be activated externally · Air actuator in the event of fault: cannot be activated · Safety time during operation: 1 s · Minimum burner on time tB: 30 s · Minimum pause time tMP: 0 s · Operating time in Manual mode limited to 5 min. · Purge (bus): via terminal · Fieldbus communication: Off · Kromschr?der Safety Link: Off Контроллер
Подробнее
Артикул: BCU 480-5/3/1LW2GB
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для pilot and main burners · 1st safety time on start-up (burner/pilot burner) tSA1: 5 s · 2nd safety time on start-up (main burner) tSA2: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7-25/20 · Front film in English with additional stickers in D, F, I, NL, E · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 05 Main burner switch-off threshold: 1 micro A · 12 Fault lock-out in the event of pilot burner failure in operation · 13 Fault lock-out in the event of main burner failure in operation · 15 Flame simulation check in start-up position/standby · 16 Permanent pilot burner · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 25 Main burner flame proving period tFS2: 0 s · 30 Air valve can be activated externally · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для single-electrode operation · Minimum time between two start-ups: 30 s Контроллер
Подробнее
Артикул: BIOA 65HB-100/35-(34)D
Бренд: Kromschroder
Описание: · Burner size 65 · Hot air/high furnace temperature · для натурального газа · Length of steel tube as of furnace flange: 100 mm · Distance from furnace flange to front edge of burner head: 35 mm · Burner head identifier 34 · Construction stage D Контроллер
Подробнее
Артикул: BCU 465-5/1LW3GBS4ACB1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Version для extended air control · Safety time on start-up tSA: 5 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 230 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-12/100 · Front film in English with additional stickers in D, F, I, NL, E · 4 start-up attempts · Air flow monitoring · With circuit board для signal distribution · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 06 Air flow monitoring during purging · 07 Air flow monitoring during operation · 39 Pre-ventilation time after safety shut-down: 0 s · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Fault lock-out in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · 37 Pre-ventilation time tVL: 0 s · 38 Post-ventilation time: 1 s · Pre-wired для double-electrode operation · Minimum time between two start-ups: 15 s Контроллер
Подробнее
Артикул: BCU 460-3/1LR8GBS2CB1/1
Бренд: Kromschroder
Описание: Разъем для on-site mounting, для controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. Для непрерывного контроля operation with ionization control or UV control using UV sensor UVD. Intermittent operation with UV sensor UVS. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, AGA, FM, EAC and CSA approved, certified для systems up to SIL 3 (compliant with PL e). · Standard version · Safety time on start-up tSA: 3 s · Safety time during operation tSB: 1 s · Air valve control · Mains voltage: 115 V AC, 50/60 Hz · Ignition transдляmer TZI 7,5-20/33 · Front film in English with additional stickers in D, F, I, NL, E · 2 start-up attempts · With circuit board для signal distribution · PROFIBUS DP interface · Integrated Variosub PROFIBUS DP chassis socket, 9-pin · 04 Switch-off threshold, burner/pilot burner: 1 micro A · 12 Restart in the event of burner failure in operation · 15 Flame simulation check in start-up position/standby · 20 Minimum burner on time tB: as safety time on start-up tSA(2) · 21 Minimum burner pause time tBP: 0 s · 23 Burner/pilot burner flame proving period tFS1: 0 s · 30 Air valve opens with V1 · 31 Air valve cannot be activated externally on start-up · 32 Air valve can be activated in the event of malfunction · 34 Burner on time in Manual mode limited to 5 min. · Pre-wired для double-electrode operation · Minimum time between two start-ups: 10 s Контроллер
Подробнее