г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

Комплектующие Kromschroder

Есть вопросы? Напишите нам.

Артикул
Описание
2487Артикул:Diode GP10Y, 1 A, 1600 V
2492Артикул:FCU 500QC0F0H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2493Артикул:FCU 500QC0F0H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 0 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 73 Function of terminal 68: safety interlock relay feedback · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2494Артикул:FCU 500WC0F0H0K0-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · No temperature monitoring · No connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2495Артикул:FCU 500WC0F0H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2496Артикул:FCU 500WC0F0H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 2 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 300 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2497Артикул:FCU 500WC0F0H1K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type N double thermocouple NiCrSi-NiSi · 23 Temperature difference limit value: 15°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 800°C · 26 Temperature hysteresis: 10°C · 27 No pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 210 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2498Артикул:FCU 500WC0F0H1K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · No capacity control · With temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 950°C · 26 Temperature hysteresis: 50°C · 27 No pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 10 s · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 50 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 80 Fieldbus communication: no address check Запасная часть
2499Артикул:FCU 500QC0F1H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 300 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2500Артикул:FCU 500QC0F1H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 300 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 10 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: AND gating with the input at terminal 46 (emergency stop) · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 73 Function of terminal 68: safety interlock relay feedback · 77 User-defined password · 80 Fieldbus communication: no address check Запасная часть
2501Артикул:FCU 500WC0F1H0K0-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · No connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2502Артикул:FCU 500WC0F1H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 100 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2503Артикул:FCU 500WC0F1H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with safety shut-down · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 No pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 150 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with IC 20 · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 70 Function of terminal 65: AND gating with the input at terminal 46 (emergency stop) · 72 Function of terminal 67: safety shut-down if no signal from automatic burner control unit · 73 Function of terminal 68: safety interlock relay feedback · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2504Артикул:FCU 500QC0F1H1K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with IC 20 · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2505Артикул:FCU 500QC0F1H1K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 300 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 10 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: AND gating with the input at terminal 46 (emergency stop) · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 73 Function of terminal 68: safety interlock relay feedback · 77 User-defined password · 80 Fieldbus communication: no address check Запасная часть
2506Артикул:FCU 500WC0F1H1K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 100 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2507Артикул:FCU 500WC0F1H1K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 10 s · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 120 s · 35 Air flow monitoring during pre-purge with safety shut-down · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with IC 40 · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: RBW High position feedback · 70 Function of terminal 65: AND gating with the input at terminal 46 (emergency stop) · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2508Артикул:FCU 500QC0F2H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для RBW · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with RBW · 41 Running time of RBW valve with 255 s timeout · 42 RBW running time: 30 s · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: RBW High position feedback · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2509Артикул:FCU 500WC0F2H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для RBW · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with safety shut-down · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 1 s · 35 Air flow monitoring during pre-purge with safety shut-down · 37 Post-purge time tPN: 1 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2510Артикул:FCU 500WC0F2H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для RBW · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 10 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2511Артикул:FCU 500WC0F2H1K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для RBW · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 5498 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with frequency converter · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2512Артикул:FCU 500QC1F0H0K0-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · No capacity control · No temperature monitoring · No connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 19 Safety time during operation: 1 s · 27 No pre-purge during high temperature operation · 29 Fan switched off in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 0 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 51 Valve proving system: tightness test beдляe start-up · 53 Tightness control test volume: Vp, venting via V3 · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 300 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password Запасная часть
2513Артикул:FCU 500QC1F0H0K1-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · No capacity control · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 51 Valve proving system: permanent tightness test via proof of closure function (POC) · 53 Tightness control test volume: Vp · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 10 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
2514Артикул:FCU 500QC1F0H0K2-E
Описание:Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · No capacity control · No temperature monitoring · Spring дляce connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 19 Safety time during operation: 1 s · 27 No pre-purge during high temperature operation · 29 Fan switched off in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 0 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 51 Valve proving system: tightness test beдляe start-up · 53 Tightness control test volume: Vp, venting via V3 · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 100 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 3 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Комплектующие Kromschroder , c 2485 по 2520,заказные номера FL 350TN2-ES /B ... L-angle bracket DL 2/4/14/35E; 3,5/4,5/8/16/24/40K,
классификация Connection flange · Size 3 · DN 50 · NPT thread · 2'' connection · Inlet · With strainer · Enclosed Запасная часть Запасная часть

Не нашли то, что искали?

Оставьте своё имя и номер телефона, и наш менеджер свяжется с вами в течение 15 минут