г. Санкт-Петербург,
пер. Ульяны Громовой, д. 4
Время работы: Офис: с 9 до 18
Склад: с 8 до 17
8 (812) 385-56-15 Звонок по России бесплатный info@fgrus.ru

FCU 500WC1F2H1K1-E Kromschroder

Артикул
FCU 500WC1F2H1K1-E
Дополнительный Артикул
FCU500WC1F2H1K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · With integrated tightness control or POC · Modulating capacity control with interface для RBW · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 53 Tightness control test volume: Vp · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 10 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Цена
277 981 руб.
Вес
0,78 кг
Теги
Protective system control

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: RFM 1,6RB100
Бренд: Kromschroder
Описание: для pressure display, positive-pressure-proof, with zero point correction, для gas and air · Measuring range: 0-1.6 bar · R external thread · Positive pressure · 100 mm visible scale diameter Запасная часть
Подробнее
Артикул: DL 3E-1
Бренд: Kromschroder
Описание: для monitoring air and flue gas pressures, для positive pressure, negative pressure and differential pressure, EU certified · Adjusting range: 0.3-3 mbar, can be used as ''special-design pressure switch'' · Flat plugs, tube connection and adjusting screw · Electrical connection via AMP plugs Запасная часть
Подробнее
Артикул: DG 6TG-22K2
Бренд: Kromschroder
Описание: Для мониторинга газа и воздушного давления, also для biologically produced methane, with hand wheel для switching point adjustment, FM and UL tested · Adjusting range: 0.2-2.4 ''WC (0.5-6 mbar) · Inch and mbar scale and NPT internal thread, red/green pilot lamp для 24 V, with gold-plated contacts · Electrical connection via screw terminals and 1/2 NPT conduit, IP 65 · Two 1/4 NPT connections · Green/red pilot lamp для 24 V AC/DC Запасная часть
Подробнее
Артикул: IFC 120/20R05-08PPPP/40A2AR10
Бренд: Kromschroder
Описание: для controlling continuously regulated burner processes, linear ratio between input signal and flow rate, control ratio 25:1, для gas and air, EU certified · Size 1 · Inlet: DN 20 (3/4'') · Outlet: DN 20 (3/4'') · Rp internal thread · pu max. 500 mbar (7 psig) · Cylinder 08 · Accessories, right: 2 screw plugs · Accessories, left: 2 screw plugs · Actuator IC 40 · Running time adjustable between 4.5 and max. 75 s · Mains voltage: 100-230 V AC, 50/60 Hz · Torque: 2 Nm · 4 – 20 mA analogue input and digital inputs · Feedback potentiometer: 1000 Ohm · Parameter set 68001, operating mode 06, 3-stage operation with one or two digital inputs, running time: 6 s · · Consisting of: · 88300203 · 88300241 Запасная часть
Подробнее
Артикул: FCU 500QC1F1H1K1-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 53 Tightness control test volume: Vp · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 10 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: AND gating with the input at terminal 46 (emergency stop) · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Подробнее
Артикул: GEH 50R50
Бренд: Kromschroder
Описание: для precise flow rate adjustment, tool-operated · DN 50 · Rp internal thread/R external thread · pu max. gas: 5 bar, air: 16 bar Запасная часть
Подробнее