FCU 500WC0F2H1K1-E Kromschroder
Артикул
FCU 500WC0F2H1K1-E
Дополнительный Артикул
FCU500WC0F2H1K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для RBW · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 5498 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with frequency converter · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Цена
230 384 руб.
Вес
0,78 кг
Теги
Protective system control
Узнайте актуальную цену данного товара
Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут