FCU 500WC0F1H1K1-E Kromschroder

Артикул
FCU 500WC0F1H1K1-E
Дополнительный Артикул
FCU500WC0F1H1K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 230 V AC, 50/60 Hz · No integrated tightness control or POC · Modulating capacity control with interface для actuator IC · With temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 20 Maximum temperature monitoring using safety temperature limiter (STL) · 22 Type K double thermocouple NiCr-Ni · 23 Temperature difference limit value: 50°C · 24 Lower limit для high temperature operation: 750°C · 25 Upper limit of the furnace or flue gas temperature: 350°C · 26 Temperature hysteresis: 50°C · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 100 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Цена
230 384 руб.
Вес
0,78 кг
Теги
Protective system control

Узнайте актуальную цену данного товара

Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут

Доставка от 3 до 10 дней

из Европы Америки и Азии

Гарантия 12 месяцев

на всё оборудование, включая б/у

Можем поставить редкое и снятое

с производства оборудование

Более 5000 брендов

поставим под заказ

Похожие товары

Артикул: GIK 40R02-5L
Бренд: Kromschroder
Описание: To maintain a constant pressure ratio of 1:1 · DN 40 · Rp internal thread · pu max. 200 mbar · Pressure test point at the outlet · для air only Запасная часть
Подробнее
Артикул: VGBF 150F05-3
Бренд: Kromschroder
Описание: Spring-loaded, with inlet pressure compensation diaphragm and zero shut-off, to maintain a constant set pressure · DN 150 · Flange to ISO 7005 · pu max. 0.5 bar · Screw plug at the inlet and outlet · для gas, EU certified · Set to 20 mbar (range: 10-30 mbar) Запасная часть
Подробнее
Артикул: DM 65Z50-160
Бренд: Kromschroder
Описание: для metering gas where no calibration is required, display of the quantity consumed, with E1 and E200 pulse generators · Nominal flow rate: 65 m3/h, measuring range: 6-100 m3/h(b) · Intermediate flange · DN 50, E1: 1 pulse/m3, E200: 250 pulses/m3 · pu max. 16 bar Запасная часть
Подробнее
Артикул: FCU 500QC1F2H0K1-E
Бренд: Kromschroder
Описание: Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · Modulating capacity control with interface для RBW · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 10 Emergency stop with fault lock-out · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 31 Fault lock-out if fan not running · 32 Air flow monitoring during controlled air flow on, valve opens · 34 Pre-purge time tPV: 6000 s · 35 Air flow monitoring during pre-purge with fault lock-out · 37 Post-purge time tPN: 6000 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 40 Capacity control with RBW · 41 Running time of RBW valve with 255 s timeout · 42 RBW running time: 30 s · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 51 Valve proving system: permanent tightness test via proof of closure function (POC) · 53 Tightness control test volume: Vp · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 10 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 69 Function of terminal 51: RBW High position feedback · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Подробнее
Артикул: DG 150B-3
Бренд: Kromschroder
Описание: Для мониторинга газа и воздушного давления, also для biologically produced methane, with hand wheel для switching point adjustment, can be used as ''special-design pressure switch'', EU certified · Adjusting range: 30-150 mbar · Switches with rising positive pressure · Electrical connection via screw terminals and M16 cable gland, IP 54 Запасная часть
Подробнее
Артикул: VGBF 25R40-1Z
Бренд: Kromschroder
Описание: Spring-loaded, with inlet pressure compensation diaphragm and zero shut-off, to maintain a constant set pressure · DN 25 · Rp internal thread · pu max. 4 bar · Screw plug at the inlet · для gas, EU certified · Special outlet pressure range Запасная часть
Подробнее