FCU 500QC1F1H0K1-E Kromschroder
Артикул
FCU 500QC1F1H0K1-E
Дополнительный Артикул
FCU500QC1F1H0K1E
Бренд
Kromschroder
Описание
Разъем для control cabinet installation, для monitoring and controlling central safety functions in multiple burner systems on industrial furnaces, long service life due to replaceable power модуль для fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft. EC-type tested and certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e). · Series 500 · Mains voltage: 120 V AC, 50/60 Hz · With integrated tightness control or POC · Modulating capacity control with interface для actuator IC · No temperature monitoring · Screw connection terminals · EU certified, CSA and FM approved, certified для systems up to SIL 3 (compliant with PL e) · Individual packaging · 12 High gas pressure protection with fault lock-out · 13 Low pressure cut-off with fault lock-out · 15 Air deficiency cut-out with fault lock-out · 19 Safety time during operation: 1 s · 27 Pre-purge during high temperature operation · 29 Fan switched on in the event of fault · 30 Fan run-up time tGV: 0 s · 32 Air flow monitoring during controlled air flow off, valve opens · 34 Pre-purge time tPV: 0 s · 37 Post-purge time tPN: 0 s · 38 Post-purge: actuator (if there is one) moves to the OPEN position and the air flow is not monitored. · 44 Controller enable signal delay time tRF: 0 s · 45 Minimum enable time: 0 s · 46 After operating signal: no controller enable · 47 Controller enable (timeout): 60 min. · 53 Tightness control test volume: Vp · 54 Tightness control: pressure reduction Vp2 in standyby · 55 Relief valve V3 opening time (tL3): 0 s · 56 Measurement time Vp: 10 s · 57 Measurement time Vp1 + Vp2: 10 s · 58 Measurement time Vp1 + Vp2 + Vp3: 3600 s · 59 Valve opening time V1 (tL1): 2 s · 60 Valve opening time V2 (tL2): 2 s · 62 Minimum pause time tfP: 0 s · 63 Switch-on delay time tE: 0 s · 65 Filling time beдляe start-up: 0 s · 67 Operating time in Manual mode limited to 5 min. · 72 Function of terminal 67: fault lock-out if no signal from automatic burner control unit · 77 User-defined password · 80 Fieldbus communication: with address check Запасная часть
Цена
209 979 руб.
Вес
0,78 кг
Теги
Protective system control
Узнайте актуальную цену данного товара
Оставьте свой E-mail и наш менеджер ответит вам в течение 15 минут